Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 942
Filter
1.
Sci Rep ; 14(1): 6598, 2024 03 19.
Article in English | MEDLINE | ID: mdl-38503795

ABSTRACT

A prototype system aimed at improving arm function and trunk control after stroke has been developed that combines mixed-reality (MR) feedback with a mobile seat system (Holoreach). The purpose of this study was to assess the usability of Holoreach in a rehabilitation setting from both the patient and therapist perspective. Ten therapists (eight physiotherapists and two occupational therapists) used the device in their regular therapy programs for fifteen stroke patients with trunk control issues. Each patient received four individual therapy sessions with the device performed under the supervision of the therapist. Therapists and patients kept therapy diaries and used customized questionnaires. At the end of the study two focus groups were conducted to further assess usability. Generally, the prototype system is suitable for training trunk and arm control. The therapists expressed overall positive views on the impact of Holoreach. They characterized it as new, motivating, fresh, joyful, interesting, and exciting. All therapists and 80% of the patients agreed with the statement that training with Holoreach is beneficial for rehabilitation. Nonetheless, improvements are required in the hardware and software, and design. The prototype system contributes at various levels to the rapidly evolving advances in neurorehabilitation, particularly regarding the practical aspect of exercise delivery.


Subject(s)
Augmented Reality , Stroke Rehabilitation , Stroke , Humans , Stroke Rehabilitation/methods , Upper Extremity , Software
2.
Heliyon ; 10(5): e26931, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38434337

ABSTRACT

A prototype visual feedback system has been developed to assess and improve movement disorders related to neck pain. The aim of this study was to assess the usability of the prototype in a rehabilitation setting. Twelve physical therapists integrated the device into their regular therapy programs for 24 neck pain patients with movement disorders. Each patient performed three individual therapy sessions with the device under physical therapist supervision. Usability was assessed by the physical therapists and patients using therapy diaries, the System Usability Scale, and focus group or personal interviews. Based on an overall usability rating of marginally acceptable, the visual feedback system was generally found to be a device with the potential to assess and train neck pain patients but needs improvement. To become a useful adjunct to regular physical therapy, improvements in the hardware and software, and further system developments are required.

3.
Phys Rev Lett ; 131(14): 142501, 2023 Oct 06.
Article in English | MEDLINE | ID: mdl-37862664

ABSTRACT

We present the measurement of the two-neutrino double-ß decay rate of ^{76}Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg yr, the half-life of the process has been determined: T_{1/2}^{2ν}=(2.022±0.018_{stat}±0.038_{syst})×10^{21} yr. This is the most precise determination of the ^{76}Ge two-neutrino double-ß decay half-life and one of the most precise measurements of a double-ß decay process. The relevant nuclear matrix element can be extracted: M_{eff}^{2ν}=(0.101±0.001).

4.
Eur Phys J C Part Fields ; 83(9): 778, 2023.
Article in English | MEDLINE | ID: mdl-37674593

ABSTRACT

We search for tri-nucleon decays of 76Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to 73Cu, 73Zn, and 73Ga nuclei, respectively. These nuclei are unstable and eventually proceed by the beta decay of 73Ga to 73Ge (stable). We search for the 73Ga decay exploiting the fact that it dominantly populates the 66.7 keV 73mGa state with half-life of 0.5 s. The nnn-decays of 76Ge that proceed via 73mGe are also included in our analysis. We find no signal candidate and place a limit on the sum of the decay widths of the inclusive tri-nucleon decays that corresponds to a lower lifetime limit of 1.2×1026 yr  (90% credible interval). This result improves previous limits for tri-nucleon decays by one to three orders of magnitude.

5.
Eur Phys J C Part Fields ; 83(4): 319, 2023.
Article in English | MEDLINE | ID: mdl-37122826

ABSTRACT

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the Gerda experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of 76 Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the Gerda liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

6.
Opt Express ; 30(11): 19904-19921, 2022 May 23.
Article in English | MEDLINE | ID: mdl-36221754

ABSTRACT

We demonstrate a free-running single-cavity dual-comb optical parametric oscillator (OPO) pumped by a single-cavity dual-comb solid-state laser. The OPO ring cavity contains a single periodically-poled MgO-doped LiNbO3 (PPLN) crystal. Each idler beam has more than 245-mW average power at 3550 nm and 3579 nm center wavelengths (bandwidth 130 nm). The signal beams are simultaneously outcoupled with more than 220 mW per beam at 1499 nm and 1496 nm center wavelength. The nominal repetition rate is 80 MHz, while the repetition rate difference is tunable and set to 34 Hz. To evaluate the feasibility of using this type of source for dual-comb applications, we characterize the noise and coherence properties of the OPO signal beams. We find ultra-low relative intensity noise (RIN) below -158 dBc/Hz at offset frequencies above 1 MHz. A heterodyne beat note measurement with a continuous wave (cw) laser is performed to determine the linewidth of a radio-frequency (RF) comb line. We find a full-width half-maximum (FWHM) linewidth of around 400 Hz. Moreover, the interferometric measurement between the two signal beams reveals a surprising property: the center of the corresponding RF spectrum is always near zero frequency, even when tuning the pump repetition rate difference or the OPO cavity length. We explain this effect theoretically and discuss its implications for generating stable low-noise idler combs suitable for high-sensitivity mid-infrared dual-comb spectroscopy (DCS).

8.
Eur Phys J C Part Fields ; 82(4): 284, 2022.
Article in English | MEDLINE | ID: mdl-35464994

ABSTRACT

The GERmanium Detector Array (Gerda) collaboration searched for neutrinoless double- ß decay in 76 Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular 228 Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in Gerda Phase II corresponding to an exposure of 103.7 kg year. These methods suppress the background by a factor of about 5 in the region of interest around Q ß ß = 2039  keV, while preserving ( 81 ± 3 ) % of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.

12.
Int J Oral Maxillofac Surg ; 51(7): 883-885, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34876334

ABSTRACT

Tracheoesophageal fistula results in persistent leakage of saliva into the trachea, prevents oral feeding, and predisposes to aspiration pneumonia. Large fistula closure may require a free flap to cover the defect. When the defect involves the tracheal area between the neck and the mediastinum, a tubeless field for optimal exposure can be advantageous. This article reports the use of veno-venous extracorporeal lung support, a known safe and efficient technique to support the patient's respiratory function, for this purpose. The typical veno-venous extracorporeal lung support setting includes a femoro-jugular bypass. The patient cases reported here had characteristics that precluded the use of the jugular vein, such as neck radiation dermatitis, previous radical neck dissection, and poor accessibility. Therefore a more rarely described femoro-femoral approach was used. The cases of three patients with persistent tracheoesophageal fistula who had free flap surgeries (two bi-paddled radial forearm free flap and one latissimus dorsi muscle free flap) assisted by femoro-femoral veno-venous extracorporeal lung support are reported.


Subject(s)
Free Tissue Flaps , Plastic Surgery Procedures , Tracheoesophageal Fistula , Humans , Laryngectomy , Lung/surgery , Tracheoesophageal Fistula/surgery
13.
Opt Express ; 29(22): 36321-36327, 2021 Oct 25.
Article in English | MEDLINE | ID: mdl-34809045

ABSTRACT

We present a high power optical parametric oscillator (OPO) synchronously pumped by the second-harmonic of a modelocked 1030-nm thin-disk laser (TDL) oscillator. The OPO delivers an average power of 51.1 W around degeneracy (1030 nm) with a 10.2-MHz repetition-rate. After extra-cavity dispersion compensation using dispersive mirrors, we obtain a pulse duration of 169 fs, which is 4.6× shorter than the TDL pulse duration of 770 fs. The TDL has 250 W average power, which is converted to 215 W at the second-harmonic. Hence, the OPO exhibits a high photon conversion efficiency of 47% (ratio of signal photons to 515-nm pump photons). Moreover, the OPO generates a peak power of 26.2 MW, which is very similar to the 28.0-MW peak power of the TDL. To facilitate continuous tuning around degeneracy and convenient extraction of the pump and idler beams, the OPO is operated in a noncollinear configuration. A linear cavity configuration was chosen since it offers easy alignment and straightforward cavity length tuning. To the best of our knowledge, this source has the highest average power generated by any ultrafast OPO, and the shortest pulse duration for any >5-W OPO. This result is an important step to adding wavelength tunability to high power Yb-based laser sources without the complexity of either laser or parametric amplifier systems.

14.
Eur Phys J C Part Fields ; 81(6): 505, 2021.
Article in English | MEDLINE | ID: mdl-34720720

ABSTRACT

Neutrinoless double- ß decay of 76 Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in 76 Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the Gerda setup. The measured resolutions at the Q-value for double- ß decay of 76 Ge ( Q ß ß  = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (Gerda) experiment and an accumulated exposure of 8.5 kg · year, the background index after analysis cuts is measured to be 4 . 9 - 3.4 + 7.3 × 10 - 4 counts / ( keV · kg · year ) around Q ß ß . This work confirms the feasibility of IC detectors for the next-generation experiment Legend.

15.
Eur Phys J C Part Fields ; 81(8): 682, 2021.
Article in English | MEDLINE | ID: mdl-34776783

ABSTRACT

The GERmanium Detector Array (Gerda) collaboration searched for neutrinoless double- ß decay in 76 Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q ß ß = 2039.061 ( 7 )  keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double- ß decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular 228 Th calibrations. In this work, we describe the calibration process and associated data analysis of the full Gerda dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.

16.
Eur Phys J E Soft Matter ; 44(10): 128, 2021 Oct 18.
Article in English | MEDLINE | ID: mdl-34661786

ABSTRACT

Thermodiffusion in ternary mixtures is considered prototypic for the Soret effect of truly multicomponent systems. We discuss ground-based measurements of the Soret coefficient along the binary borders of the Gibbs triangle of the highly polar and hydrogen bonding ternary DCMIX3-system water/ethanol/triethylene glycol. All three Soret coefficients decay with increasing concentration, irrespective of the choice of the independent component, and show a characteristic sign change as a function of temperature and/or composition. With the exception of triethylene glycol/ethanol at high temperatures, the minority component always migrates toward the cold side. All three binaries exhibit temperature-independent fixed points of the Soret coefficient. The decay of the Soret coefficient with concentration can be related to negative excess volumes of mixing. The sign changes of the Soret coefficients of the binaries allow to draw far-reaching conclusions about the signs of the Soret coefficients of the corresponding ternary mixtures. In particular, we show that at least one ternary composition must exist, where all three Soret coefficients vanish simultaneously and no steady-state separation is observable.

17.
Adv Exp Med Biol ; 1269: 31-38, 2021.
Article in English | MEDLINE | ID: mdl-33966191

ABSTRACT

Hypoxic ischaemic encephalopathy (HIE) is a significant cause of death and disability. Therapeutic hypothermia (TH) is the only available standard of treatment, but 45-55% of cases still result in death or neurodevelopmental disability following TH. This work has focussed on developing a new brain tissue physiology and biochemistry systems biology model that includes temperature effects, as well as a Bayesian framework for analysis of model parameter estimation. Through this, we can simulate the effects of temperature on brain tissue oxygen delivery and metabolism, as well as analyse clinical and experimental data to identify mechanisms to explain differing behaviour and outcome. Presented here is an application of the model to data from two piglets treated with TH following hypoxic-ischaemic injury showing different responses and outcome following treatment. We identify the main mechanism for this difference as the Q10 temperature coefficient for metabolic reactions, with the severely injured piglet having a median posterior value of 0.133 as opposed to the mild injury value of 5.48. This work demonstrates the use of systems biology models to investigate underlying mechanisms behind the varying response to hypothermic treatment.


Subject(s)
Hypothermia, Induced , Hypoxia-Ischemia, Brain , Animals , Bayes Theorem , Hypoxia-Ischemia, Brain/therapy , Oxygen , Swine , Systems Biology
18.
Appl Ergon ; 94: 103390, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33640840

ABSTRACT

A prototype assistive therapy chair (T-Chair) that induces exercise stimuli to improve trunk control and standing and walking early after stroke has been developed. The aim of this study was to assess its usability in a rehabilitation setting. Eleven physical therapists (PTs) integrated the T-Chair into the therapy programs of 15 patients post stroke. Each patient performed on average four individual therapy sessions on the T-Chair under the PTs' supervision. Usability was assessed using questionnaires, therapy diaries and focus group interviews with PTs'. Among PTs', 64% had generally a positive view on the T-Chair. Physical therapists recognized the potential for unsupervised therapy. Generally, patients reacted positively and enjoyed training. The T-Chair has the potential to become an adequate training tool for patients with an intermediate trunk control after stroke. Further development and usability testing are required to provide a therapeutic device allowing for an intensive therapy early post stroke.


Subject(s)
Neurological Rehabilitation , Physical Therapists , Stroke Rehabilitation , Stroke , Humans , Perception
19.
BMC Bioinformatics ; 21(1): 582, 2020 Dec 17.
Article in English | MEDLINE | ID: mdl-33334310

ABSTRACT

BACKGROUND: Biomedical research projects deal with data management requirements from multiple sources like funding agencies' guidelines, publisher policies, discipline best practices, and their own users' needs. We describe functional and quality requirements based on many years of experience implementing data management for the CRC 1002 and CRC 1190. A fully equipped data management software should improve documentation of experiments and materials, enable data storage and sharing according to the FAIR Guiding Principles while maximizing usability, information security, as well as software sustainability and reusability. RESULTS: We introduce the modular web portal software menoci for data collection, experiment documentation, data publication, sharing, and preservation in biomedical research projects. Menoci modules are based on the Drupal content management system which enables lightweight deployment and setup, and creates the possibility to combine research data management with a customisable project home page or collaboration platform. CONCLUSIONS: Management of research data and digital research artefacts is transforming from individual researcher or groups best practices towards project- or organisation-wide service infrastructures. To enable and support this structural transformation process, a vital ecosystem of open source software tools is needed. Menoci is a contribution to this ecosystem of research data management tools that is specifically designed to support biomedical research projects.


Subject(s)
Biomedical Research , Data Management/methods , Software , Databases, Factual , Information Storage and Retrieval
20.
Psychiatry Res Neuroimaging ; 304: 111151, 2020 10 30.
Article in English | MEDLINE | ID: mdl-32738724

ABSTRACT

The neural mechanism of phantom limb pain (PLP) is related to the intense brain reorganization process implicating plasticity after deafferentation mostly in sensorimotor system. There is a limited understanding of the association between the sensorimotor system and PLP. We used a novel task-based functional magnetic resonance imaging (fMRI) approach to (1) assess neural activation within a-priori selected regions-of-interested (motor cortex [M1], somatosensory cortex [S1], and visual cortex [V1]), (2) quantify the cortical representation shift in the affected M1, and (3) correlate these changes with baseline clinical characteristics. In a sample of 18 participants, we found a significantly increased activity in M1 and S1 as well as a shift in motor cortex representation that was not related to PLP intensity. In an exploratory analyses (not corrected for multiple comparisons), they were directly correlated with time since amputation; and there was an association between increased activity in M1 with a lack of itching sensation and V1 activation was negatively correlated with PLP. Longer periods of amputation lead to compensatory changes in sensory-motor areas; and itching seems to be a protective marker for less signal changes. We confirmed that PLP intensity is not associated with signal changes in M1 and S1 but in V1.


Subject(s)
Motor Cortex/physiopathology , Phantom Limb/physiopathology , Somatosensory Cortex/physiopathology , Adult , Female , Humans , Magnetic Resonance Imaging , Male , Motor Cortex/diagnostic imaging , Neuronal Plasticity/physiology , Phantom Limb/diagnostic imaging , Phantom Limb/pathology , Sensorimotor Cortex/diagnostic imaging , Sensorimotor Cortex/physiopathology , Somatosensory Cortex/diagnostic imaging , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...